0
    0
    Il tuo carrello
    Il carrello è vuotoRitorno al negozio
      Calcolo della spedizione
      Applica il Coupon
      Vai al contenuto principale

      Come utilizzare un adattatore Smart-Y in modo sicuro


      Many marinas don’t have a dedicated 100A receptacle, requiring you to combine two 50A outlets to power your yacht. This is where a Smart-Y Adapter becomes indispensable.

      What is a Smart-Y Adapter?
      A Smart-Y Adapter combines two separate 50A 120/240V shore power receptacles into a single 100A supply. Unlike a simple Y-splitter, a Smart-Y includes automatic paralleling control that checks phase alignment.

      Why Phase Checking Matters
      If the two outlets are on different phases or wired incorrectly, connecting them without protection can:

      • Damage sensitive equipment
      • Cause dangerous voltage imbalances
      • Trip breakers or create fire hazards

      Steps for Safe Use

      1. Inspect Both Outlets:
        Use a polarity tester to confirm proper wiring.
      2. Connect One Cord at a Time:
        Plug in each 50A cord carefully.
      3. Verify the Indicator:
        ANG Smart-Y Adapters have status indicators to confirm correct phase alignment.
      4. Secure the Cords:
        Keep connections dry and strain-relieved.
      5. Monitor Load:
        Avoid running high-startup equipment all at once.

      ANG Advantage
      ANG Smart-Y Adapters feature:

      • IP56-rated enclosures
      • Automatic phase detection and correction
      • Robust marine-grade connectors
      • Compact design for easy stowage

      Tip:
      Never use a basic splitter without verification—it’s not worth the risk.