Description
Délai de livraison : 1-3 jours ouvrables
Contrôleur automatique de parallèle - monophasé
ENTRÉE : Deux 50A 120/240V 60Hz Deux 50A 0/230V 50Hz
SORTIE : Un 100A 120/240V 60Hz Un 100A 0/230V 50Hz
_
WARNINGS
The unit may not work on docks with GFCI protection.
Always connect and disconnect both 50 Amp 120/240V cables simultaneously.
Please don’t use Smart-Y if a transformer or converter isn’t installed on board.
DO NOT USE with one 50 Amp only.
CAUTION – risk of electric shock.
NEVER TOUCH EXPOSED PLUG BLADES IF THE OTHER IS CONNECTED.
The Smart-Y is designed to operate at 120V/240V, 50/60Hz. Proper functionality is not guaranteed when connected to three-phase systems (e.g., 208V), and use with such configurations is not recommended. The Smart-Y is intended for single-phase or split-phase applications only and is not compatible with three-phase power.
To CONNECT: Place both breakers of the power pedestal outlets in the OFF position, connect the Input 1 and 2 plugs and the load plug to the 100 Amp Output, and finally turn ON both breakers on the dock pedestal.
To DISCONNECT: turn off both dock breakers and disconnect the Input 1 and 2 plugs, as well as the plug connected to the 100 Amp Output.
This device must always be powered (Input 1 and 2) through 50 Amp breakers.
This device does not protect against overloads or short circuits that may be produced by the load connected to the 100 Amp Output.
This device does not provide galvanic isolation; therefore, you should use an isolation transformer.